x Items in my bag 0
    Menu
    Menux
    SPEEDY DELIVERY Nationwide TRADE SERVICE Dedicated account managers BESPOKE BUILD Get a free quote

    1250 Litre Steel Bunded Diesel Dispensing Tank

    Fluids
    D
    O
    HVO
    (View Key)
    Availability 10-15 Days
    Highlights

    Integrally bunded Diesel Dispenser

    240v 56lpm Transfer pump included

    4 Metre Delivery hose

    Auto shut off nozzle

    2" BSP Fill Point

    Lockable door

    Dimensions: 2,330L x 640W x 1,540H

    Weight: 249Kg

    Brimful Capacity: 1,283 Litres

    Manufacturer Code TEB1250
    Colour
    Tank Stand Legs
    Code
    You May Also Need
    Cim-Tek Tank Drying Sock
    Price 12.80 15.36 inc VAT

    The Cim-Tek Tank Dryer is a fuel tank water absorber, which has been developed in response to the increasing concerns regarding water contamination of fuel. By checking for, and removing any unwanted water, the Tank Dryer reduces the damaging impact that this contamination has on machinery and vehicles. The Tank Dryer, or ‘tank sock’ as it is often referred to, contains highly absorbent silica gel, which when lowered into the tank absorbs up to 350ml of water. 

    read more...
    CTS Fuel Re-circulation Pump
    Price 1,491.60 1,789.92 inc VAT

    The CTS Fuel Recirculation Unit was developed to prevent diesel fuel inside a storage tank from getting stagnant - particularly those with low usage such as generator back up tanks, that whilst not regularly used are of vital importance. When fuel sits stagnant for long periods of time, microbial growth known as diesel bugs begin to form, join together and create a nasty biofilm. By keeping the fuel moving and free of the contaminants that can get sucked into pumps, equipment and vehicles, costly damage and downtime can be avoided. 

    The fuel storage tank circulation system draws the fuel up from the front of the tank through the magnetic conditioner, which stuns the bugs, breaking them down into a size that will pass through a two stage water and particle filtration process to remove any impurities. The cleaner fuel is then circulated back into the tank, before the bugs have been able to group and create the nasty sludge. 

    The CTS storage tank recirc unit has an input for connecting to an alarm/gauge to detect a low fuel level and a leak probe for a drip tray (if installed). Benefiting from a control panel with large, coloured lights, any issues that need to be dealt with i.e. filter blocked, low fuel level, a leak or a system fault can be easily diagnosed. If the system identifies any of the above issues, the pump will turn off until necessary action has been taken as a safeguard. Complete with two BMS outputs, the control panel can also send a signal of this to warn users remotely.

    There are two versions of CTS Fuel Tank Circulation System; one for circulating (50lpm) a maximum of 3000 litres per day for tanks up to 40,000 litres, and another for circulating (70lpm) a maximum of 4000 litres per day for tanks up to 70,000 litres. Tank contents should be recirculated every 28 days to prevent bacteria colonies from forming. Our systems are set to turn over 1.5 times the tank contents every 28 days to include a safety margin.

    read more...
    CTS Economy Tank Bund Alarm
    Price 78.42 94.10 inc VAT

    The CTS Economy Tank Bund Alarm is an entry level, battery powered bunded fuel tank alarm system designed to alert of the presence of fluid between the inner tank and its outer bund. Essentially, its purpose is to detect and warn that either the inner tank has ruptured and is leaking, or that there is excess rain water within the tank's bund. This is a simple and cost effective solution if only a bund alert is required, and the customer is not concerned with being warned of a tank level scenario. Upon activation, a red LED will flash and a 90db alarm will sound to warn the user that the tank's bund needs to be cleared and checked whether there is a leak.

    This fuel tank alarm, which comes in a weatherproof enclosure, features a test button that will activate the sounder to check the battery and a mute button to silence the sounder. Thanks to its simple operation, the battery will last in excess of 72 hours in full alarm mode, and approximately 2 years when in standby, making it ideal for sites that aren't always manned.

    read more...
    Price 2,482.95 2,979.54 inc VAT
    Description

    The TEB range offers a simple solution to the problems generally encountered with providing watertight bunds around tanks. Both the inner and outer tanks are constructed from mild steel plate to BS EN 10025.

    The inner tank providing the required storage area, the outer tank forms the required bund, with capacity of 110% of the total liquid being stored. The tank’s fill point and pump feed is piped directly into the tank’s distribution cabinet which also houses the pump and associated equipment. The tank vent is piped into the bund then to atmosphere further reducing the risk of spills in the event of overfilling the tank.  Steel base plinths are also fitted to eliminate any ground contact with the sump base.

    Manufactured in the UK from Mild Steel Plate, these Steel Bunded Diesel Dispensing Tanks Come complete with -

    230v 56lpm Pump

    4 Metre Delivery Hose

    Auto Shut off Nozzle

    Water/Particle Filter

    Bund Gauge

    Contents Gauge

    2" BSP Fill Point with Cap

    Vent Cap

    Cabinet with Lockable Door

    10 Year Guarantee

    Compliancy:

    BS799 part 5,

    Control of pollution (oil storage) (England) regulations 2001

    PPG2

    PPG26

    Product Specification
    Global
    Capacity: 1250
    Material: Steel
    Tank Type: Bunded

    1250 Litre Steel Bunded Diesel Dispensing Tank

    1250 Litre Steel Bunded Diesel Dispensing Tank