    86,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    86,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 59,700.00 71,640.00 inc VAT

    Tuffa Tanks 86,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 6mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 86000SBFP comes complete with:

    Integral 60 Minute fire Protection

    1 Metre deep cabinet with roller shutter door

    3" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    47,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    47,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 45,310.00 54,372.00 inc VAT
    Options

    Tuffa Tanks 47,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 6mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 47000SBFP comes complete with:

    Integral 60 Minute fire Protection

    1 Metre deep cabinet with roller shutter door

    3" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    31,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    31,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 32,620.00 39,144.00 inc VAT
    Options

    Tuffa Tanks 30,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 6mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 30000SBFP comes complete with:

    Integral 60 Minute fire Protection

    1 Metre deep cabinet with roller shutter door

    3" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    20,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    20,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 22,185.00 26,622.00 inc VAT
    Options

    Tuffa Tanks 20,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 6mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 20000SBFP comes complete with:

    Integral 60 Minute fire Protection

    Lockable fill point cabinet

    2" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    15,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    15,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 17,250.00 20,700.00 inc VAT
    Options

    Tuffa Tanks 15,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 6mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 15000SBFP comes complete with:

    Integral 60 Minute fire Protection

    Lockable fill point cabinet

    2" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    10,000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    10,000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 12,230.00 14,676.00 inc VAT
    Options

    Tuffa Tanks 10,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 3mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 10000SBFP comes complete with:

    Integral 60 Minute fire Protection

    Lockable fill point cabinet

    2" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    5000 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    5000 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 9,180.00 11,016.00 inc VAT
    Options

    Tuffa Tanks 5,000 Litre Steel fire protected heating oil tanks are manufactured in the UK from hard wearing 3mm mild steel. This tank is fitted with a 60 minute fire rated material between the bund and and the inner tank which protects the contents of the tank for a minimum of 60 minutes should there be a fire. With a 10 year guarantee, and a life expectancy of over 30 years when properly installed and maintained, these tanks provide an economical solution to suit most installations. 

    The Tuffa 5000SBFP comes complete with:

    Integral 60 Minute fire Protection

    Lockable fill point cabinet

    2" BSP Fill point with Cap & Chain

    Tank Vent

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Contents Reading Gauge

    Battery bund & overfill alarm (Optional 230v version with contents gauge)

    Lifting eyes

    Channel Runners

    Bottom Outlet Fitting Kit

    Grey RAL 7001 Paint Finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified.

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    2300 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    2300 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 2,938.00 3,525.60 inc VAT
    Fire Resistance
    Outlet Option
    Delivery Options

    Tuffa Tanks 2,300 Litre fire protected heating oil tanks are manufactured in the UK from 3mm Mild steel. With a life expectancy of 30 years, they provide an economical solution to suit most installations. 

    These Tanks come complete with:

    Integral 30 or 60 Minute fire Protection

    2" BSP Fill point with Cap & Chain

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Float Level Clock Gauge

    Watchman Sonic Gauge

    Central Lifting Eye

    Channel Runners

    Bottom Outlet Fitting Kit

    Green RAL6005 Paint finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified. This means they can be located within 1,800mm of a window, shed and flue outlet, or within 760mm of a non-fire rated boundary (eg. wooden fence)

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Domestic: 

    30 minute fire protection – install a domestic tank adjacent to buildings and boundaries

    60 minute fire protection – install a domestic tank inside an uninhabited building such as a garage (pending installer/inspector approval)

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    30 minute fire protection - Enables the installation of an oil tank a minimum of 300mm from other buildings and structures. Where access is required, then a minimum distance of 600mm is required.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    1800 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    1800 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 2,750.00 3,300.00 inc VAT
    Fire Resistance
    Outlet Option
    Delivery Options

    Tuffa Tanks 1,800 Litre fire protected heating oil tanks are manufactured in the UK from 3mm Mild steel. With a life expectancy of 30 years, they provide an economical solution to suit most installations. 

    These Tanks come complete with:

    Integral 30 or 60 Minute fire Protection

    2" BSP Fill point with Cap & Chain

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Float Level Clock Gauge

    Watchman Sonic Gauge

    Central Lifting Eye

    Channel Runners

    Bottom Outlet Fitting Kit

    Green RAL6005 Paint finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified. This means they can be located within 1,800mm of a window, shed and flue outlet, or within 760mm of a non-fire rated boundary (eg. wooden fence)

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Domestic: 

    30 minute fire protection – install a domestic tank adjacent to buildings and boundaries

    60 minute fire protection – install a domestic tank inside an uninhabited building such as a garage (pending installer/inspector approval)

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    30 minute fire protection - Enables the installation of an oil tank a minimum of 300mm from other buildings and structures. Where access is required, then a minimum distance of 600mm is required.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

     

    read more...
    quick view
    1100 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    1100 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 2,440.00 2,928.00 inc VAT
    Fire Resistance
    Outlet Option
    Delivery Options

    Tuffa Tanks 1,100 Litre fire protected heating oil tanks are manufactured in the UK from 3mm Mild steel. With a life expectancy of 30 years, they provide an economical solution to suit most installations. 

    These Tanks come complete with:

    Integral 30 or 60 Minute fire Protection

    2" BSP Fill point with Cap & Chain

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Float Level Clock Gauge

    Watchman Sonic Gauge

    Central Lifting Eye

    Channel Runners

    Bottom Outlet Fitting Kit

    Green RAL6005 Paint finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified. This means they can be located within 1,800mm of a window, shed and flue outlet, or within 760mm of a non-fire rated boundary (eg. wooden fence)

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Domestic: 

    30 minute fire protection – install a domestic tank adjacent to buildings and boundaries

    60 minute fire protection – install a domestic tank inside an uninhabited building such as a garage (pending installer/inspector approval)

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    30 minute fire protection - Enables the installation of an oil tank a minimum of 300mm from other buildings and structures. Where access is required, then a minimum distance of 600mm is required.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...
    quick view
    900 Litre Tuffa Steel Fire Protected Oil Tank
    D
    K

    900 Litre Tuffa Steel Fire Protected Oil Tank

    Availability 8 Weeks
    Price 2,232.00 2,678.40 inc VAT
    Fire Resistance
    Outlet Option
    Delivery Options

    Tuffa Tanks 900 Litre fire protected heating oil tanks are manufactured in the UK from 3mm Mild steel. With a life expectancy of 30 years, they provide an economical solution to suit most installations. 

    These Tanks come complete with:

    Integral 30 or 60 Minute fire Protection

    2" BSP Fill point with Cap & Chain

    Overfill Prevention Valve

    1" BSP Bottom outlet

    Float Level Clock Gauge

    Watchman Sonic Gauge

    Central Lifting Eye

    Channel Runners

    Bottom Outlet Fitting Kit

    Green RAL6005 Paint finish

    Tuffa's fire-protected oil tanks come fitted with an integral bund as standard and are LABC Certified. This means they can be located within 1,800mm of a window, shed and flue outlet, or within 760mm of a non-fire rated boundary (eg. wooden fence)

    Tuffa's Steel Bunded Fire-Protected Oil Tanks must be installed to building standards.

    Fire Protection

    Domestic: 

    30 minute fire protection – install a domestic tank adjacent to buildings and boundaries

    60 minute fire protection – install a domestic tank inside an uninhabited building such as a garage (pending installer/inspector approval)

    Non-Domestic:

    60 minute fire protection – install a non-domestic tank adjacent to buildings and boundaries

    Tuffa’s fire protected oil tanks serve as an alternative means of compliance when compared to traditional fire barriers. Tuffa’s fire protected tank system has LABC certification proving compliance with local authorities across Britain. However, it is the responsibility of the Competent Person installing the tank, or the building inspector certifying the installation, to ensure a site-specific risk assessment has been conducted.

    30 minute fire protection - Enables the installation of an oil tank a minimum of 300mm from other buildings and structures. Where access is required, then a minimum distance of 600mm is required.

    60 minute fire protection - Enables the installation of an oil tank within a garage or other internal space where it is impractical to install the tank externally to the building. The tank must be installed in an uninhabitable area (e.g. a garage or outbuilding), at the lowest possible level in the building or structure. Additionally, the tank must be installed a minimum of 300mm from other internal walls and structures or 600mm where access is required.

    read more...