x Items in my bag 0
    Menu
    Menux
    Our office will be closed from 5th - 9th August for our summer shutdown.
    Emails will be monitored but our phone lines will be unavailable. Orders will be dispatched where possible.

    Cylindrical Fuel Storage Tanks

    Cylindrical fuel tanks are used to store various fuels including diesel and hydrotreated vegetable oil (HVO). Available in a choice of capacities, cylindrical tanks offer a reliable way to safely store larger quantities of fuel on site and are suitable for a range of commercial applications.
    Filter By
    quick view
    4000 Litre CEMO Steel Bunded Cylindrical Diesel Storage Tank
    D
    O
    B1

    4000 Litre CEMO Steel Bunded Cylindrical Diesel Storage Tank

    Availability On Request
    Price £15,969.00 £19,162.80 inc VAT

    The CEMO 4000 Litre Bunded above ground storage tank is manufactured from Mild steel to DIN6616/D. Suitable for Diesel and Biodiesel, the CEMO 7580 Comes complete with -

    Welded Steel Saddle Feet

    Painted & Primed Exterior (Different colours available on request)

    Access Ladder

    Dip Stick for level monitoring

    Extraction pipe in dome lid

    Anti-syphon Device

    Bund Alarm with Liquid Control

    Overfill Prevention Sensor

    Factory Test Certificate

    10 Year Warranty

    read more...
    quick view
    5,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    5,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £17,274.00 £20,728.80 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    7,500 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    7,500 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £18,606.00 £22,327.20 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    10,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    10,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £21,327.00 £25,592.40 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    15,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    15,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £23,961.00 £28,753.20 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    22,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    22,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £29,006.00 £34,807.20 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    27,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    27,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £31,436.00 £37,723.20 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    32,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    32,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £33,713.00 £40,455.60 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    42,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    42,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £39,823.00 £47,787.60 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    50,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    50,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £42,621.00 £51,145.20 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    quick view
    60,000 Litre NTS Cylindrical Diesel Fuel Tank
    D
    K
    O
    HVO
    B1

    60,000 Litre NTS Cylindrical Diesel Fuel Tank

    Availability Built to Order
    Price £50,362.00 £60,434.40 inc VAT
    Cabinet

    This Horizontal, cylindrical bulk diesel tank with a double skin design is constructed from mild steel plate to BS EN 10025.

    The inner tank provides the required storage area, whilst the outer tank forms the required bund with capacity of 110% of the total liquid being stored. The tank vent is piped into the bund and then to the atmosphere further reducing the risk of spills in the event of overfilling the tank.

    These tanks are fitted with steel base supports to eliminate ground contact with the tank base.

    This Cylindrical fuel tank can be supplied with either a lockable fill point cabinet or full size inset cabinet to house any ancillary equipment fitted with lockable steel or roller shutter door.

    Specification:

    1 x 2” tank to bund vent.   1 x 2” atmospheric vent with cap.   1 x Bund contents test and drain point with dial gauge. 1 x 2” Base feed with isolation valve.   1 x 2” Top feed with foot valve and strainer.   1 x 2” socket for tank contents. 1 x 2” Socket fill point.   4 x lift points (lift empty only).   1 x 1” socket in bund for optional bund alarm probe.

    1 x 2” socket in top of tank for optional high / low alarm probes.     1 x 600mm Service hatch.     Base support: Tank support cradles with ground anchor points.

    Paint finish: ISO 12944 C3 Compliant coating. Application design life: 7 years. Typical environments include: Urban and industrial atmospheres, Moderate sulphur dioxide levels, production areas with humidity.

    Compliancy:

    BS799 Part 5. PPG2, DSEAR 2002

    Control of Pollution (Oil Storage) (England) Regulations,

    Environment (Oil Storage) (Scotland) Regulations,

    Control of Pollution (Oil Storage) Regulations (Northern Ireland),

    Control of Pollution (Oil Storage) (Wales) Regulations.

    read more...
    Cylindrical Fuel Storage Tanks

    High Quality Cylindrical Fuel Tanks

    We stock a wide range of quality cylindrical fuel storage tanks at Northern Tank Store to meet a range of requirements. Whether you need a 5,000-litre fuel storage tank or a 50,000-litre storage tank, we build solutions to order with surprisingly short lead times, so you can always get exactly what you need when you need it.

    Tanks are made to meet or exceed all relevant regulations, and manufactured to provide many years of trouble free service. We also offer a comprehensive range of diesel tanks including dispensing tanks, as well as all the accessories and equipment you need to store, manage and use fuel on-site. 

    Safe & Secure Fuel Storage Solutions

    Fuel and other materials stored in cylindrical tanks are potentially hazardous, flammable and dangerous to the environment. That is why we prioritise safety and security with all of our fuel storage tanks - to ensure safety on-site and to maintain environmental responsibility.

    We design and manufacture our cylindrical fuel storage tanks to prevent possible leakages or spills that can be a risk to personnel and damage the environment. We use the latest industry innovations and technology to produce fuel storage solutions that are built to work reliably, so you can store the fuel you need safely over extended periods without worrying about leakages. Models include useful features such as overfill valves, lockable fill point cabinets for security, and access ladders.

    If you are looking at high capacity cylindrical fuel storage tanks, you should know that they cannot legally be installed without being bunded. Our cylindrical tanks include double skin construction to protect from leaks and spillages, while steel supports minimise ground contact for extended lifespans.

    Cylindrical Fuel Tanks From Northern Tank Store

    As one of the UK’s leading manufacturers and suppliers of fuel storage solutions, at Northern Tank Store you can find a range of cylindrical tanks that offers quality, value and reliability. We have decades of experience in providing all kinds of businesses with the fuel storage solutions they need, so browse or range online or get in touch with our team to find out more about how we can help you.

    TOP
    CLOSE X
    Thank you for subscribing to our newsletter