-
sales@northerntankstore.co.uk
- Call: 01748 835276
-
Heating Oil Tanks
- Single Skin Tanks
- Fire Rated Oil Tanks
-
Bunded Oil Tanks
- Steel Bunded Oil Tanks
- Plastic Bunded Oil Tanks
- Slimline Bunded Oil Tanks
- Low Profile Bunded Oil Tanks
- 500 & 650 Litre Bunded Oil Tanks
- 1000 Litre Bunded Oil Tanks
- 1200 & 1225 Litre Bunded Oil Tanks
- 1300, 1400 & 1500 Litre Bunded Oil Tanks
- 2000 Litre Bunded Oil Tanks
- 2500 Litre Bunded Oil Tanks
- View All Bunded Oil Tanks
- Heating Oil Accessories
- Oil Tank Offers
- View All Heating Oil Tanks
- Diesel Tanks
- Petrol Tanks
- AdBlue Tanks
- Water & Chemical
- Waste & Lube Oil
- Septic Tanks & Water Treatment
- Settlement Tanks
- General Storage
- Spill Control
- Tank Accessories
-
Heating Oil Tanks
- Single Skin Tanks
- Steel Single Skin Tanks
- Plastic Single Skin Tanks
- Slimline Single Skin Tanks
- Low Profile Single Skin Tanks
- Fire Rated Oil Tanks
- Steel Fire-Proof Oil Tanks
- Plastic Fire-Proof Oil Tanks
- Bunded Oil Tanks
- Steel Bunded Oil Tanks
- Plastic Bunded Oil Tanks
- Slimline Bunded Oil Tanks
- Low Profile Bunded Oil Tanks
- 500 & 650 Litre Bunded Oil Tanks
- 1000 Litre Bunded Oil Tanks
- 1200 & 1225 Litre Bunded Oil Tanks
- 1300, 1400 & 1500 Litre Bunded Oil Tanks
- 2000 Litre Bunded Oil Tanks
- 2500 Litre Bunded Oil Tanks
-
Diesel Tanks
- Dispensing Tanks
- Steel Dispensing Tanks
- Plastic Dispensing Tanks
- Dispensing Containers
- Portable Dispensing Tanks
- Fuel Storage Tanks
- Steel Fuel Storage Tanks
- Plastic Fuel Storage Tanks
- Cylindrical Fuel Storage Tanks
- Fuel Bowsers
- Road Legal Tow Bowser
- Site Tow Bowsers
- Fixed Skid Bowsers
- Generator Tanks
- Static Generator Fuel Tanks
- Transportable Generator Tanks
- Generator Stores
- Petrol Tanks
- AdBlue Tanks
-
Water & Chemical
- Potable Water Tanks
- 1-100 Litre Potable Water Tanks
- 101-650 Litre Potable Water Tanks
- 651+ Litre Potable Water Tanks
- Water Bowser Tanks
- Trailed Water Bowsers
- Fixed Skid Bowsers
- Water Storage Tanks
- 1-100 Litre Water Storage Tanks
- 101-650 Litre Water Storage Tanks
- 651+ Litre Water Storage Tanks
- Water Tank Accessories
- Water Pumps & Hoses
- Water Tank Fittings
- Waste & Lube Oil
- Septic Tanks & Water Treatment
- Settlement Tanks
- General Storage
- Spill Control
-
Tank Accessories
- Flow Meters
- Mechanical Flow Meters
- Digital Flow Meters
- Pulse Meters
- Transfer Pumps
- Diesel Transfer Pumps
- Oil Transfer Pumps
- AdBlue Transfer Pumps
- Water Pumps
- Petrol Pumps
- Chemical Pumps
- Hand Pumps
- Electric Pumps
- Air Operated Pumps
- Fuel Nozzles
- Diesel Nozzles
- Oil Nozzles
- Petrol Nozzles
- AdBlue Nozzles
- Water Nozzles
- Chemical Dispensing Nozzles
- Automatic Nozzles
- Manual Nozzles
- Tank Alarms & Overfill Valves
- Alarms
- Probes
- Overfill
- Fill Point & Vent Fittings
- Fuel Tank Fill Caps
- Fuel Tank Vent Caps
- Hose & Hose Reels
- Delivery Hose
- Suction Hose
- Hose Reels
- Hose Fittings
- Breakaway Couplings
- Camlock Couplings
- Tank Gauges
- Float Type Gauges
- Hydrostatic Gauges
- Electronic Gauges
- Sight Gauges
- Pipe Fittings
- Brass Fittings
- Stainless Steel Fittings
- Steel & Iron Fittings
- Fuel Management Systems
- Management Units & Systems
- Software & Accessories
- Valves
- Gate Valves
- Lever Ball Valves
- Pressure Valves
- Check Valves
- Solenoid Valve
- Drum/IBC Valves
- Cabinets
- Fill Point Cabinets
- Dispensing Cabinets
- Garage Equipment
- Oil Drainers & Extractors
- Drum Trolleys & Dispensers
Apollo Smart Ultrasonic Tank Gauge
The CTS AdBlue™ Tank und Alarm is an economy, entry level, battery powered AdBlue™ tank alarm system for alerting the user to fluid being detected between the inner tank and the outer bund. If only a bund alert is needed for your tank, this bund alarm is a simple, cost-effective solution and doesn't involve the other warnings associated with a fuel tank level alarm. A red LED will flash and a 90db alarm will sound to alert the user to fluid being detected in the bund - which can be caused by a tank rupture/leak or rainwater collecting in the bund - meaning your bund will need cleaning and/or emptying.
This battery powered AdBlue&trade bund alarm allows 72 hours of full alarm mode, making it ideal for unmanned sites and those with site closure on weekends. Further features include a weatherproof enclosure and test and alarm mute buttons to silence the sounder.
The Fuel Recirculation Unit was developed to prevent diesel fuel inside a storage tank from getting stagnant - particularly those with low usage such as generator back up tanks, that whilst not regularly used are of vital importance. When fuel sits stagnant for long periods of time, microbial growth known as diesel bugs begin to form, join together and create a nasty biofilm. By keeping the fuel moving and free of the contaminants that can get sucked into pumps, equipment and vehicles, costly damage and downtime can be avoided.
The fuel storage tank circulation system draws the fuel up from the front of the tank through the magnetic conditioner, which stuns the bugs, breaking them down into a size that will pass through a two stage water and particle filtration process to remove any impurities. The cleaner fuel is then circulated back into the tank, before the bugs have been able to group and create the nasty sludge.
The storage tank recirc unit has an input for connecting to an alarm/gauge to detect a low fuel level and a leak probe for a drip tray (if installed). Benefiting from a control panel with large, coloured lights, any issues that need to be dealt with i.e. filter blocked, low fuel level, a leak or a system fault can be easily diagnosed. If the system identifies any of the above issues, the pump will turn off until necessary action has been taken as a safeguard. Complete with two BMS outputs, the control panel can also send a signal of this to warn users remotely.
There are two versions of Fuel Tank Circulation System; one for circulating (50lpm) a maximum of 3000 litres per day for tanks up to 40,000 litres, and another for circulating (70lpm) a maximum of 4000 litres per day for tanks up to 70,000 litres. Tank contents should be recirculated every 28 days to prevent bacteria colonies from forming. Our systems are set to turn over 1.5 times the tank contents every 28 days to include a safety margin.
The Aluminium Fuel Tank Vent Cowl is designed to fit over the male thread on the top of an above ground storage tank to provide ventilation. These vent cowls come three lugs for direct fitting, one with an Allan key screw fitting to help secure the cowl to the male thread of the tank.
The Aquafighter Finger is a fuel tank water absorber designed to remove both the free and suspended/emulsified water from fuel tanks onboard small industrial machines, agricultural machinery and plant equipment when they are not in use.
With the increasing bio content in diesel, water contamination is one of the largest causes of engine damage, as it causes microbial growth that results in a nasty sludge responsible for filter blockages, equipment damage, engine corrosion and poor fuel efficiency. The Aquafighter water absorber eliminates these problems by reducing the water content levels down to 75ppm to meet the EN590 diesel fuel standards (200ppm), saving you costly damage and downtime. Unlike other solutions on the market, this diesel tank water absorber not only absorbs free water but separates and captures the suspended emulsified water in the fuel, which often gets left to cause serious damage to your vehicles and equipment.
By acting in this way, the Aquafighter Finger fuel tank water absorber provides numerous benefits including preventing diesel bug from forming, reducing filter replacement requirements and the need for a regular tank cleaning, and protecting the tank from corrosion.
Please note: If this is your first time using Aquafighter, we recommend buying 2 units. The first can be added to absorb the current water, which may become full quickly if there is a large problem with water. The second to be added once the other has been removed to act as a prevention against future water content.

.jpg)


